Smarthome SUPERVISED WIRELESS SECURITY CONSOLE PS561 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Bezpieczeństwo Smarthome SUPERVISED WIRELESS SECURITY CONSOLE PS561. Smarthome SUPERVISED WIRELESS SECURITY CONSOLE PS561 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
L
*p()WE’HO~I’E
‘y
PS561
OWNER’S MANUAL
SUPERVISED WIRELESS SECURITY CONSOLE
and accessories (sold separately)
J
PS561
Security Console
KF574
Keychain
Remote
HT544
Remote
Control
SH624
Remote Control
0
tm1
Yn
ORAY
m
II
0
cd.
[-lo)
DW534
Door/Window Sensor
PH508 Remote Siren
SP554 Motion Detector
LM465
Lamp
Module
Smarthome.com, Inc. (800)
SMART-HOME (949) 221-9200
http://smarthome.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 32 33

Podsumowanie treści

Strona 1 - SMART-HOME (949) 221-9200

L*p()WE’HO~I’E ‘y PS561 OWNER’S MANUALSUPERVISED WIRELESS SECURITY CONSOLEand accessories (sold separately)JPS561 Security ConsoleKF574KeychainRemoteH

Strona 2 - CONTENTS

WindowsNote: For sliding windows it is best tomount the magnet and switch at thebottom of the window with the arrowsfacing each other. This way the ma

Strona 3 - AND F.C.C. CAUTIONS

SETTING UP AND USING MOTION DETECTORSThis procedure initializes each MotionDetector so that the Console recogniz-es it. You install a Motion Detectorj

Strona 4 - INTRODUCTION

MOTION DETECTOR PLACEMENTD~i$Y~.)Nominal Zonal Coverage (Ran View)9i&GA9 12 1518 21 24 27 30 33 36 39Zone B Zone C Zone DNominal Zonal Coverage (S

Strona 5 - --I=--41

SETTING UP REMOTE MODULESSETTING UPLAMP MODULESWhen the alarm trips, lamps connect-ed to Lamp Modules (set to the sameHousecode as the Console) flash

Strona 6 - REMOTE CONTROL(S)

POWERHORN REMOTE SIRENSETTING UP THE POWERHORNThe POWERHORN Remote Powerlinesiren responds to signals transmittedby the Console (over house wiring).Wh

Strona 7

SETTING UP THE TELEPHONE DIALERSetting Up Phone NumbersWarning: Only program the Consoleto call someone with whom you havediscussed your Security Syst

Strona 8 - WINDOW SENSOR(S)

USING THE SYSTEMCONSOLEZONE INDICATORSThe Console displays the status of thefirst eight zones. These indicators candisplay four states, as follows:Ste

Strona 9 - INSTALLING SENSORS

3. Press [DISARM] to stop the siren.The lights remain on.4. Press [LIGHT OFF] on the RemoteControl to turn off lights connectedto modules which you se

Strona 10

ARMING WITHOUT THEREMOTE CONTROLYou can arm the system without usinga Remote Control by pressing theARM button on the Console. Armingthis way will ALW

Strona 11

TESTING THE DIALEROnce you have installed the Sensorsand Remote Controls, and entered thephone numbers and the voice mes-sage, the Console is ready to

Strona 12 - MOTION DETECTOR PLACEMENT

CONTENTSU.L. and F.C.C. Cautions 3Introduction 4Installing the System 5Locating the Console 5Setting up the Console 5Setting up Remote Controls 6HT544

Strona 13 - SETTING UP REMOTE MODULES

TURNING LIGHTS ON ANDOFF REMOTELYHT544/KF574 Remote ControlPress [LIGHT ON] or [LIGHT OFF]on the Remote Control to turn on oroff lights connected to X

Strona 14 - POWERHORN REMOTE SIREN

THIS IS X-10 POWERHOUSEDoor/Window Sensor (DW534)Up to 16 Door/Window Sensors canbe installed and you can connect morethan one door or window to a sen

Strona 15

Sixteen Plus”” Remote (RT504)Controls up to 16 modules from insideor outside your home - even from yourcar as you enter your driveway. Canalso dim and

Strona 16 - USING THE SYSTEM

Mini Timer (MT522)Instantly controls up to eight X-10modules and programs up to fourmodules to turn on and off at specifictimes. Can turn lights on at

Strona 17 - ARM HOME/ARM AWAY

SUNDOWNERTM (SD533)Turns on up to 4 modules at dusk andturns them off again at dawn. Also hasall the features of the Mini Controller(MC460).Telephone

Strona 18

Split Receptacle Module (SR227)Replaces your existing outlet andworks like an Appliance Module. Rat-ed at 15 Amps unrestricted. Top outletis controlle

Strona 19 - TESTING THE DIALER

CARE AND MAINTENANCEYour supervised security system is an example of superior design and craftsman-ship. The following suggestions will help you care

Strona 20 - OFF REMOTELY

REPLACING BATTERIESREMOTE CONTROL DOOR/WINDOW SENSORSFor HT544 use 9V alkaline battery.For KF574 use 6V Eveready A544,Radio Shack 23-469, or equivalen

Strona 21 - THIS IS X-10 POWERHOUSE

ing the new battery. This ensures thatthe sensor is logged into its originalzone number.MOTION DETECTORSIf any of the Console’s zone indicatorsflash s

Strona 22

TROUBLESHOOTINGIf the system does not arm:l Check that the selector switch onthe Console is in the RUN 1 orRUN 2 position.l Check that the battery ind

Strona 23 - It doesn’t tie

U.L. AND F.C.C. CAUTIONSFCC Caution: This equipment generatesand uses radio frequency energy, and if notinstalled and used properly, that is, in stric

Strona 24 - (SD533)

If you cannot turn lights on or offfrom the [Light On] or [Light Off]buttons on the Remote Control:Be sure you set the Housecode andUnit Code on the m

Strona 25

If you do not want this to happen, setthe Appliance Module(s) to a differentHousecode from the one you set onthe Console.If you do not hear a beep fro

Strona 26 - CARE AND MAINTENANCE

If red light on sensor/motion detec-tor stays on during installation:Press [CODE] then press [TEST]. If itstill stays on, remove the battery, waita fe

Strona 27 - REPLACING BATTERIES

and someone answers the phoneand presses any key, the Console isput into the listen mode for 75 sec-onds. If you immediately call theperson back or if

Strona 28 - MOTION DETECTORS

INTRODUCTIONThe PS561 Security Console is part ofa Supervised Security System and isused with the following accessories,(sold separately).Hand-held Re

Strona 29 - TROUBLESHOOTING

INSTALLING THE SYSTEMLOCATING THE SETTING UP THECONSOLE CONSOLESelect a location that is central to thedoors and windows you wish to pro-tect so that

Strona 30 - Check that the magnet is not

SETTING UPREMOTE CONTROL(S)This procedure initializes each Re-mote Control so that the Console rec-ognizes its commands.HT544 Remote Control1.2.3.4.In

Strona 31

SH624 Security/Home AutomationRemote Control1.2.3.Install four AAA alkaline batteries [CODE] button under here.in the SH624’s battery compart-ment.I/

Strona 32 - POWERHORN

SETTING UP DOOR/WINDOW SENSOR(S)This procedure initializes each Door/Window Sensor so that the Consolerecognizes signals from the sensor.1.2.3.4.5.6.7

Strona 33

INSTALLING SENSORS1.2.3.4.5.6.Set the switch on the front of theDoor/Window Sensor to MIN ifyou are using it to protect a win-dow or to MAX if you are

Komentarze do niniejszej Instrukcji